Ingredients

GRAPHITE

CAS: 7782-42-5

RTECS: MD9659600

OSHA PEL 15 MG/M3 T DUST

ACGIH TLV: 2 MG/M3 R DUST


MANGANESE DIOXIDE

CAS: 1313-13-9

RTECS: OP0350000

OSHA PEL C 5 MG (MN)/M3

ACGIH TLV: 0.2 MG(MN)/M3


POTASSIUM HYDROXIDE

CAS: 1310-58-3

RTECS: TT2100000

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


ZINC

CAS: 7440-66-6

RTECS: ZG8600000

OSHA PEL RF 5 MG/M3 R DUST

ACGIH TLV: RF 3 MG/M3 R DUST

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS

Hazards

Health Hazards Acute and Chronic:UNDER NORMAL CONDITIONS OF USE, THE
BATTERY IS HERMETICALLY SEALED. INGESTION: SWALLOWING A BATTERY CAN
BE HARMFUL. CONTENTS OF AN OPEN BATTERY CAN CAUSE SERIOUS CHEMICAL
BURNS OF MOUTH, ESOPHAGUS, AN D GASTROINTESTINAL TRACT. INHALATION:
CONTENTS OF AN OPEN BATTERY CAN CAUSE RESPIRATORY IRRITATION. SKIN
CONTACT: CONTENTS OF AN OPEN BATTERY CAN CAUSE SKIN IRRITATION AND
/ OR CHEMICAL BURNS. EYE CON TACT: CONTANTS OF AN OPEN BATTERY CAN
CAUSESEVERE IRRITATION AND CHEMICAL BURNS.
Effects of Overexposure:CONTENTS OF AN OPEN BATTERY CAN CAUSE SERIOUS
CHEMICAL BURNS OF MOUTH, ESOPHAGUS, AND GASTROINTESTINAL TRACT,
RESPIRATORY IRRITATION, SKIN AND EYE IRRITATION AND BURNS.

First Aid

First Aid:INGESTION: IF BATTERY OR OPEN BATTERY IS INGESTED, DO NOT
INDUCE VOMITING OR GIVE FOOD OR DRINK. SEEK MEDICAL ATTENTION
IMMEDIATELY. CALL NATIONAL BATTERY INGESTION HOTLINE FOR ADVICE AND
FOLLOW-UP (2 02-625-3333) COLLECT, DAY OR NIGHT. INHALATION: MOVE
TO FRESH AIR, SEEK MEDICAL HELP. SKIN CONTENT: REMOVE CONTAMINATED
CLOTHING, WASH SKIN WITH SOAP AND WATER. IF A CHEMICAL BURN OCCURS
ORIRRITATION PERSISTS, SEEK MEDICAL HELP. EYE CONTACT: IMMEDIATLEY
FLUSH WITH WATER FOR 15 MINUTES, LIFTING EYELIDS. SEEK MEDICAL
ATTENTION.

Fire Fighting

Extinguishing Media: IT IS PERMISSIBLE TO USE ANY CLASS OF
EXTINGUISHING MEDIUM ON THESE BATTERIES OR THEIR PACKING MATERIAL.
COOL EXTERIOR OF BATTERIES IF EXPOSED TO FIRE TO PREVENT RUPTURE.
Fire Fighting Procedures:FIRE FIGHTERS SHOULD WEAR SELF-CONTAINED
BREATHING APPARATUS.

Handling

Handling and Storage Precautions:STORAGE: STORE IN COOL, WELL
VENTILATED AREA. ELEVATED TEMPERATURES CAN RESULT IN SHORTENED
BATTERY LIFE. HANDLING: ACCIDENTAL SHORT CIRCUIT FOR A FEW SECONDS
WILL NOT SERIOUSLY AFFECT BATTERY. PROLON GED SHORT CIRCUIT WILL
CAUSE BATTERY TO LOSE ENERGY AND CAN CAUSE SAFETY RELEASE VENT TO
OPEN.
Other Precautions:SOURCES OF SHORT CIRCUITS INCLUDE BATTERIES IN BULK
CONTAINERS, METAL JEWELRY, METAL COVERED TABLES OR METAL BELTS USED
FOR ASSEMBLY INTO DEVICES. BATTERY IS MANUFACTURED IN CHARGED STATE
AND NOT DESI GNED FOR RECHARGING, RECHARGING CAN CAUSE LEAKAGE,
HIGH PRESSURE RUPTURE. CHARGING CAN OCCUR IF INST ALLED BACKWARDS.

Exposure Controls

Respiratory Protection:NOT NECESSARY UNDER NORMAL CONDITIONS.
Ventilation:NOT NECESSARY UNDER NORMAL CONDITIONS.
Protective Gloves:NOT NECESSARY UNDER NORMAL CONDITIONS. USE NEOPRENE
OR NATURAL RUBBER
Eye Protection:NOT NECESSARY NORMALLY. SAFETY GLASSES WITH SIDE SHIELDS
IF HANDLING OPEN UNITS
Supplemental Safety and Health
LYNTRONICS P/N: 7747390-10. THIS IS THE SAME BATTERY AS P/N URT 33 BA.

Chemical Properties

HCC:Z7
Appearance and Odor:8 VOLT RECTANGULAR NON-RECHARGEABLE BATTERY.

Disposal

Waste Disposal Methods:DISPOSE IN ACCORDANCE WITH ALL APPLICABLE
FEDERAL, STATE AND LOCAL REGULATIONS. APPROPRIATE DISPOSAL
TECHNOLOGIES INCLUDE INCINERATION AND LANDFILLING.

Other Information

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.

Transport

Transport Information:THE TRANSPORTATION OF DRY CELL BATTERIES
MANUFACTURED BY EVEREADY BATTERY COMPANY IS NOT REGULATED BY THE
U.S. DEPARTMENT OF TRANSPORTATION OR THE MAJOR INTERNATIONAL
REGULATORY BODIES.

Regulatory

SARA Title III Information:AS AN ARTICLE, THIS BATTERY AND ITS CONTENTS
ARE NOT SUBJECT TO THE REQUIREMENT OF THE EMERGENCY PLANNING AND
COMMUNITY RIGHT-TO-KNOW ACT.
State Regulatory Information:(CONTD FROM "OTHER INFO") YOUR EVEREADY
REPRESENTATIVE FOR PRECAUTIONARY SUGGESTIONS. BATTERIES NORMALLY
EVOLVE HYDROGEN WHICH, WHEN COMBINED WITH OXYGEN FROM AIR, CAN
PRODUCE COMBUSTIBLE OR EXPLOSIVE MIXTURE UNLESS VENTED. IF SUCH A
MIXTURE IS PRESENT, SHORT CIRCUITS, HIGH TEMPERATURE, OR STATIC
SPARKS CAN CAUSE AN IGNITION. DO NOT OBSTRUCT SAFETY VENTS ON
BATTERIES. ENCAPSULATION (POTTING) OF B ATTERIES WILL NOT ALLOW
CELL VENTING AND CAN CAUSE HIGH PRESSURE RUPTURE. IF SOLDERING OR
WELDING TO BATTERY IS REQUIRED, CONSULT YOUR EVEREADY
REPRESENTATIVE FOR PRECAUTIONS TO PREVENT SEAL DAMAGE OR SHORT
CIRCUIT.